| Dimensions |
26.25 cm × 14.19 cm × 11.93 cm (10.3 × 5.6 × 4.7 in) |
| Weight (with battery) |
~1.6 kg (3.5 lb) |
| Battery Type |
Li-ion (BP290), 10.8 V, 2,500 mAh (27 Wh) |
| Ingress Protection (IP Rating) |
IP40 (IEC 60529) |
| Safety Standards |
IEC/EN 61010-1, IEC 61010-2-030, IEC 61010-2-034; CAT III 600 V / CAT IV 300 V |
| Performance Standards |
IEC/EN 61557-1 to IEC/EN 61557-8 and IEC 61557-10 |
| Voltage Measurement (AC/DC) |
Up to 600 V; resolution 0.1 V; input impedance 320 kΩ; overload protection 660 V |
| Frequency Measurement |
45–66 Hz; resolution 0.1 Hz |
| Continuity Testing (Rlow) |
Ranges: 20 Ω / 200 Ω / 2000 Ω; resolution: 0.01 Ω / 0.1 Ω / 1 Ω; open-circuit voltage >4 V |
| Insulation Resistance (Riso) |
Test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V; ranges up to 1000 MΩ; resolution: 0.01 MΩ / 0.1 MΩ / 1 MΩ |
| Insulation Ramp Test (SPD) |
0–500 V and 0–1000 V ramps; 1 V resolution; ±(1.5% + 3 digits); 1 mA current |
| Earth Resistance Testing (RE) |
Ranges: 200 Ω / 2000 Ω; resolution: 0.1 Ω / 1 Ω; frequency 128 Hz; output voltage 25 V |
| Loop & Line Impedance Testing |
Ranges: 10 Ω to 2000 Ω; resolution: 0.001 Ω to 1 Ω; Hi-Current ±2%, No-Trip ±3–6% |
| PEFC / PSC Calculation |
Up to 50 kA; resolution 1 A (<1000 A), 0.1 kA (≥1000 A); calculated from voltage and impedance |
| Voltage Drop Measurement |
0.0–99.9%; resolution 0.1% |
| RCD Testing |
Types AC, A, F, B, B+, RDC-DD, GFCI; test modes x½, x1, x5, ramp, auto; accuracy ±5% |
| Phase Sequence Indication |
185–600 V; display “1-2-3” (correct) or “3-2-1” (incorrect) |
| Connectivity |
USB-C, Bluetooth BLE; Fluke Connect™ and TruTest software support |
| Data Functions |
Z-Max memory; auto-test logic; cloud reporting via Fluke Connect™ |