The Megger MIT2500 2.5kV insulation and continuity tester has been designed for motor and cable testing, specialist applications and electrical testing applications, where operation voltages exceed 1000 V and higher insulation test voltages are needed.
The MIT2500 offers both fixed range voltages of 50 V, 100V, 250 V, 500 V, 1000 V and 2500 V, as well as a variable range that allows any voltage between 50 V and 2500 V to be “dialled in”. This is supported by the new test voltage feedback control, which maintains the output test voltage to within 2% of the selected range, even when under test.
Key Features:
- Insulation testing up to 2.5 kV and 200 GΩ range in a hand held instrument
- Guard terminal for high resistance accuracy
- Adjustable insulation test voltage from 50 V to 2500 V
- Stabilised insulation test voltage
- Rechargeable options for mains and car charging
- Single range, faster continuity testing from 0.01 Ω to 1 MΩ
- Polarisation Index (PI) & Dielectric Absorption Ratio (DAR)
- CAT IV 600 V applications
Note: The free manufacturer calibration certificate is issued on the date of manufacture. If you require a personalised or independently tested certificate issued on the date of purchase, please select the relevant calibration option above.
Technical Specifications
Insulation | |
---|---|
Insulation Accuracy | 50 Volts: 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ 100 Volts: 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ 250 Volts: 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ 500 Volts: 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ 1000 Volts: 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ 2500 Volts: 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ Service Error: BS EN 61557-2 (2007). 50V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.5% 100V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 250V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 500V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 1000V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 11.5% |
Guard Terminal Performance | <5% erros on 500kΩ parallel circuit resistance with 100MΩ load |
Display Range | Analogue: 1GΩ full scale |
Short Circuit/Charge Current | 2mA +0 to -50% t EN 61557-2 (2007) (except 2500V) |
Terminal Voltage Accuracy | -0 +2% ±2V |
Test Current | 1mA at minimum pass values of insulation to a maximum of 2mA max |
Operation | EN61557: 0.10MΩ to 1.0GΩ |
Leakage Current Display | 10% ±3 digits |
Voltage | ±3% ±2 digits ±0.5% of rated voltage |
Timer Control | Countdown timer 60 seconds (adjustable to 10 minutes) |
Note | Above specs only apply when high quality silicone leads are used |
Continuity | |
Continuity Measurement | 0.01Ω to 1MΩ (0 to 1000kΩ on analogue scale) |
Continuity Accuracy | ± 3% ± 2 digits (0 to 100 Ω ) ± 5% ± 2 digits (100 Ω - 500 k Ω) Service Error: BS EN 61557-4 (2007) - ± 2.0%, 0.1Ω - 2Ω ± 6.8% |
Open Circuit Voltage | 5V ±1V |
Test Current | 200mA (-0mA to +20mA) (0.01Ω to 4Ω) |
Polarity | Single polarity (default) / dual polarity (configurable on setup) |
Lead Resistance | Null Up to 10Ω |
Voltage | |
Voltage Range | DC: 0 to 600V AC: 10mV to 600V TRMS sinusoidal (15Hz to 400HZ) Unspecified: 0 to 10mV (15 to 400Hz) |
Voltage Range Accuracy | DC: ±2% ±2 digits AC: ±2% ±2 digits Service Errors: BS EN 61557-1 (2007) - ±2.0% ±2d. 0V to 300V AC/DC ±5.1% |
Waveform | Non-sinusoidal: ± 3% ± 2 digits >100 mV to 600 V TRMS ± 8% ± 2 digits 10 mV to 100 mV TRMS |
Frequency | |
Measurement Range | 15 to 400Hz |
Accuracy | ±0.5% ± 1 digit |
Capacitance | |
Range | 0.1nF to 10μF |
Accuracy | ±5.0% ±2 digits (1nf to 10μF) |
General Specifications | |
Storage Capacity | >1000 test results |
Data Download | Bluetooth wireless Bluetooth class II |
Range | Up to 10m |
Power Supply | 6 x 1.5V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) alkaline 6 x 1.2 NiMH rechargeable cells may be used |
Battery Life | 3000 insulation tests with duty cycle of 5 sec ON/55 sec OFF @ 1000V into 1MΩ Charger (optional) 12-15V DC (accessory interface) |
Dimensions | 228 x 108 x 63mm |
Weight | 815g |
Fuse | Use only 2 x 500mA (FF) 1000V 32 x 6mm ceramic fuse of high breaking capacity HBC 30kA minimu, Glass fuses MUST NOT BE FITTED |
Safety Protection | Meets EN 61010-1 (1995) to 600V phase to earth, Category IV. Refer to safety warnings supplied |
EMC | In accordance with IEC 61326 including amendment No 1 |
Temperature Coefficient | <0,1% per °C up to 1 GΩ <0,1% per °C per GΩ above 1 GΩ |
Operating Temperature Range | -10 to +55°C |
Storage Temperature Range | -25 to +70°C |
Humidity | 90% RH at 40°C max |
Calibration Temperature | +20°C |
Maximum Alititude | 2000m |
IP Rating | IP54 |
- Megger MIT2500 2.5kV Insulation Tester
- Red/Black/Blue silicone test leads with prods and clips
- 2.5 kV Red/Black/Blue silicone test leads with clips
- Owner’s Information CD
- Batteries 6 x AA Alkaline
- Carry Case