Best selling hand held PAT tester, with simple one button operation.
If you need a simple and easy-to-use PAT tester to carry out your portable appliance testing, the Seaward Primetest 100 is an ideal solution. Featuring a 3 button operation for either
Class I, Class II or leads, test selection is easy.
The large LCD display shows both a test result as well as a Pass or Fail indication in the form of a tick or a cross, making PAT testing fast and simple.
The Primetest 100 is one of our best selling PAT testers and is currently being used in schools, offices and any application where there are only a small number of appliances to test.
Click Here to see just how easy it is to PAT test with the Primetest 100
The Seaward Primetest 100 performs the legal minimum requirements for PAT testing and is suitable for use on all 240V equipment, including IT products such as PCs, fax machines, photocopiers and printers.
Carrying out earth bond tests on IT equipment with the Seaward Primetest 100
The design of the Primetest 100 PAT tester means that there is no need for a separate test process for IT equipment. The earth bond current is only 200mA, as recommended in the IEE Code of Practice, meaning that whether testing standard appliances, or IT equipment, using the Class I test button will perform the required tests.
The Seaward Primetest 100 portable appliance tester includes the following:
Seaward Primetest 100
6 x AA Batteries
Earth Bond Lead
Soft Carry Case
240V Extension Lead Adaptor
1000 PASS Labels
500 FAIL Labels
Specification
Earth Bond Test (IT Safe)
Test Current: +/- 200mA DC
Display Range: 0.00ohm - 19.99ohm
Pass Value: 0.2ohm
Insulation Resistance
Test Voltage: 500V DC
Display Range: 0.20Megohm - 19.99Megohm
Pass Value: 1Megohm Class I, 2Megohm Class II
IEC & Extension Lead Test
Earth Continuity: +/- 200mA DC
Insulation Test: 500V DC
Wiring Test: Live, Neutral Continuity& Polarity
Equivalent Leakage Test - Class I
Test Voltage: 40V AC Nominal
Display Range: 0.10mA - 19.99mA
Pass Value: 0.75mA
Equivalent Leakage Test - Class II
Test Voltage: 40V AC Nominal
Display Range: 0.10mA - 19.99mA
Pass Value: 0.25mA
Power Socket Test
Input Voltage Range: 230V +10%, -15% AC
Indicators: Phase to Earth Voltage, Phase to Neutral Voltage, Neutral to Earth